Questions and answers of the customers
There are no questions yet. Be the first to ask a question about this product.
WELCOME TO FIRESUPPLIES !
Detection
Dräger Multi gas detector X-am 2500 with NO2 and SO2 Including Power pack & Charging set
AED 8,925.00 VAT included
BW Honeywell RIGRAT HRRD102009ABK-000 Transportable Multi-gas Area Monitor
AED 28,350.00 VAT included
GasAlertMax XT-PC1 Replacement Pump Enclosure With Screw
AED 315.00 VAT included
Solo 808-001 Smoke Detector Test Starter Kit 3 Metres
AED 4,147.50 VAT included
Emergency & Exit Lights
Denko CEL 11NM WP LED Compact Emergency Light
Denko CEL 11NM LED Compact Emergency Light
Denko CEL 11M LED Compact Maintained Emergency Light
Fire Extinguishers
Hanging Type Steel Fire Extinguisher Stand
AED 603.75 VAT included
FireGuard FGP4R - 4Kg Dry Powder Fire Extinguisher
AED 68.25 VAT included
Bristol WE9 Water Fire Extinguisher - 9 Ltr (BSI-Kitemark)
AED 183.75 VAT included
Sprinklers & Fire Fighting
SIBCA-100mm Flow Switch UL/FM Listed-VDRS-100
AED 346.50 VAT included
Fire Pump 750 GPM @ 12 bar Horizontal Type, Set (1electric + 1 Diesel + 1 jockey ) UL Listed & DCD Approved
AED 131,250.00 VAT included
Shield - Grooved Reducing Coupling - SDG-30
AED 47.25 – AED 199.50Price range: AED 47.25 through AED 199.50 VAT included
Safety Gears
Canasafe iMPactor I Full Brim Twizloc Yellow
AED 44.45 VAT included
3M Hard Hat 4-Point Ratchet Suspension
AED 56.97 VAT included
3M H700 Hard Hat Ratchet Suspension - Red
AED 56.97 VAT included
Others
Fireblitz FBB120-HP 1.2m x 1.2m Fire Blanket
AED 57.75 VAT included
Nuova Rade Fresh Water Tank 70lt 700x400x260mm
AED 389.90 VAT included
Mobiak MBK03-P3 Filter Suitable for Dust, Humidity, Smoke, Aerosol
AED 64.05 VAT included
Wireless
Elotec ROYAL MM 1000 Wireless Manual Call Point
AED 787.50 VAT included
Cygnus CYG2 Fire Call Point Alarm
AED 2,164.05 VAT included
Cygnus CYG2F Fire Call Point Alarm with First Aid Alert
AED 2,526.69 VAT included
AED 3,944.85 VAT included
Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display, a 2 digit numeric display, an audible sounder, clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.
The Display Module can be mounted into a detector unit, a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.
There are various versions of the display module depending on the type of detector and the relay configuration required. The VESDA VLS display has a fourth mode for the Numerical Display which shows the First Alarm Sector (FAS), this being the number of the sector (pipe) that has detected smoke. For the VESDA VLC the Fire 2 LED is omitted.
In stock
Above AED1000 in Dubai
For 365 days
Only Reputed Brands
Multiple payment options
Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display, a 2 digit numeric display, an audible sounder, clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.
The Display Module can be mounted into a detector unit, a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.
There are various versions of the display module depending on the type of detector and the relay configuration required. The VESDA VLS display has a fourth mode for the Numerical Display which shows the First Alarm Sector (FAS), this being the number of the sector (pipe) that has detected smoke. For the VESDA VLC the Fire 2 LED is omitted.
Smoke Indication
Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke. The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 1/20 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1, Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to
triggering the next level of alarm.
Status Lights
High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly, any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified, rectified and the system reset.
X
There are no questions yet. Be the first to ask a question about this product.
There are no reviews yet.
Detection
Emergency Lights
Fire Extinguishers
Extinguisher Types
Sprinklers & Fire Fighting
Safety Gears
Safety Gears
Others
Wireless
CD Approved
No products in the cart.
Reviews
There are no reviews yet.